Mod Description
Just in case you can't read GermanMod Details
PremiumNo Difficulty Mod ID828 Creditevilution For Linkhttps://dev.evilution.co.uk/mod/chargecooler-fluid-info.htm Copy to ClipboardInformation
Like the engine, the chargecooler has to run on a mixture of water (coolant), glycol (antifreeze) to stop it getting too hot in the summer and stop it from freezing in the winter and a anti corrosion additives to stop the cooler from rotting from the inside out.
If you just used water in the chargecooler you would soon have troubles. As soon as the temperature goes below 0 °C the water would freeze.This would stop the pump from spinning which will cause it to burn out and when water turns to ice it expands which can split the metal fins inside the charge cooler or the cooling radiator.
Fluid Data
The label on the chargecooler does explain what is required but a lot is lost in translation. The short, easy to understand version is 50% antifreeze, 50% water. This is good to protect the system from freezing all the way down to -37°C.
You can mix your own if you wish using normal tap water if you don’t live in a hard water area. Cheap mineral water is a good option if you live in a hard water area.
The easier method is to buy premixed coolant. Ensure it is a 50:50 mix and is suitable for aluminium. Premixed engine coolant from smart will be fine but probably over priced.
Approved Antifreeze
Smart have a document for engine coolant/antifreezes called Sheet 325.0
Concentrate
Product Name | Country |
Addinol Antifreeze Super | Germany |
Agip Langzeit-Frostschutz | Germany |
Aral Antifreeze Extra | Germany |
Avia Antifreeze APN | Germany |
Fuchs Fricofin Antifreeze | Germany |
Genantin Super | Germany |
Glysantin Anti Korrosion | Germany |
Glysantin G48 | Germany |
Glysantin Mit Protect Plus | Germany |
Hightec Antifreeze AN | Germany |
MB 325.0 000 989 08 25 | Germany |
MB 325.0 000 989 21 25 | Germany |
Procar Kuhlerschutz Extra | Germany |
BP Isocool | England |
Castrol Antifreeze NF | England |
Glycoshell | England |
Glycoshell N | England |
Agip Antifreeze Extra D | Italy |
Agip Antifreeze Plus | Italy |
Glacelf MDX | France |
Powercooling Concentrate Antifreeze | France |
Total Antifreeze and Summer Coolant | France |
York 716 | France |
EuroPeak Coolant Antifreeze | USA |
Mobil GS 333 Extra | USA |
Valvoline Antifreeze Extra | USA |
Zerex G05 | USA |
Zerex G48 | USA |
Engen Antifreeze and Summer Coolant | South Africa |
Engman’s – Super Antifreeze Coolant | South Africa |
Sasol Freezol | South Africa |
Shell Tri Guard | South Africa |
Krafft Refrigerant ACU 2300 | Spain |
Anticongelante Diator Premium | Mexico |
Antifreeze RL-Plus | Mexico |
Caltex CX Antifreeze Coolant | Belgium |
Aseol Antifreeze | Switzerland |
ESA Frostschutz G05 | Switzerland |
ESA Antifreeze G48 | Switzerland |
Motorex Antifreeze G05 | Switzerland |
Motorex Antifreeze Protect G48 | Switzerland |
Panolin Anti-Frost MT-325 | Switzerland |
Behran Zagros | Iran |
Dragon Power Coolant A | Korea |
Eurol Afrostin | Austria |
OMV Kuhlerfrostschutz | Austria |
EVOX Extra G48 Antifreeze Concentrate | Hungary |
Fridex G48 | Czech Republic |
INA Antifriz Al Super | Croatia |
Permant 100 | Bosnia |
PO Ozel Antifriz | Turkey |
Premixed
Product Name | Country |
BASF Coolant G05-23/50 | Germany |
Total Coolelf MDX-37 | France |
Smart A 000 989 08 25 | UK |
Fluid Level
Smart have never suggested the correct capacity of fluid for this system. At a guess I’d say 2.5 litres.
The level of the chargecooler fluid should be checked monthly for signs of fluid loss. Although losing all the fluid won’t really affect the engine all that much, running the system dry or having an airlock in particular areas of the system could cause the motor to overheat or burn out.
The level should be kept around the bottom of the filler neck. The small air gap allows for expansion of the fluid through trapped air but allows the system to retain a slight pressure.
If you drain and refill the system you will notice the level will fall over a week or so as you use the car. This is because the trapped air is being forced through the system and eventually collects in the chargecooler. Just top it up each time until the level stops dropping.